MPPT Solar Controller 12V-48V
Model | BML40415 | BML60415 | BML80415 | BML100415 | |
---|---|---|---|---|---|
System voltage | 12V/24V/36V/48V | ||||
Rated current | 40A | 60A | 80A | 100A | |
Charging mode | MPPT max power point tracking | ||||
Applicable battery type | Lead acid batter/lithium battery/water battery | ||||
Charging method | Three stages: constant cairent rent foltage, floating charge | ||||
PV Input Max open circuit voltage(VOC) | DC150V | ||||
Starting time | ≤10s | ||||
Dynamic response recovery time | ≤500us | ||||
No load consumption | ≤4W | ≤8W | |||
MPPT tracking efficiency | ≥99.5% | ||||
Max efficiency | ≥98% | ||||
System identified voltage range | 8~64V | ||||
Max power point operating voltage range |
12V | 20~150VDC | |||
24V | 36~150VDC | ||||
36V | 48~150VDC | ||||
48V | 64~150VDC | ||||
Rated charging power |
12V | 540W | 800W | 1040W | 1300W |
24V | 1080W | 1600W | 2080W | 2600W | |
36V | 1620W | 2400W | 3120W | 3900W | |
48V | 2160W | 3200W | 4160W | 5200W | |
Load voltage | Same as Battery Voltage | ||||
Rated load current | 40A | ||||
Load control method |
Normally ON/OFF mode
Time control mode
Light control mode
|
||||
Low voltage protection |
10.5V*N(N stands for batteries number)
Parametercan be adiustable
|
||||
Cooling | Air Cooling | ||||
Display | HD LCD backlight display | ||||
Protections |
Over&low-voltage protection, anti-reverse protection.
over-temperature protection,over load protection
|
||||
Temperature compensation coefficient | 一3mV/℃/2V | ||||
Communication Port | RS485 | ||||
Working temperature | '-20℃~50℃ | ||||
Storage temperature | '-40℃~70℃ | ||||
Noise (dB) | ≤50dB | ||||
Humidity | 0~90%RH | ||||
Working altitude | 0~3000M | ||||
Product Size (L*W*H)mm | 219*260*110 | 275*348*109 | |||
Net Weight KG | 2.8 | 4.6 | 5.2 | ||
Recommended wire specification | 7AWG/10mm² | 6AWG/16mm² | 4AWG/25mm² | 2AWG/35mm² | |