BCM-1500 Modified Sine Wave Inverter

Model:BCM-1500 Modified Sine Wave Inverter


It is a modified sine wave inverter and provides 1500 w continuous DC to AC power and 3000 w surge power.   

1. Aluminum-magnesium alloy shell, lightweight, good thermal conductivity, can quickly reduce the temperature of components,

2. Smart Digital Display: Show Input Voltage, Power, Temperature, and Protection code in time. The protection code as: P-1: Overload Protection; P-2: Low voltage protection; P-3: Over voltage protection; P-4:    Overheat protection; P-5: Short-circuit protection P-6: System Fault

3. Intelligent Silent Cooling Fan: It can minimize noises and extend the life of the inverter

4. Buzzer reminder: Once any protection mode of the inverter is triggered, the inverter will immediately disconnect the output voltage, and the buzzer reminds users that the inverter is in the protection mode.

5. Automatic shutdown protection and unique circuit to protect against Over-Voltage/Low-Voltage/Over-load/Short Circuit/Over Heat/Reverse Polarity

6. Supports a wide range of input voltage, which is suitable for different Battery types such as GEL, AGM, LFP, etc.

7. Double Input voltage design according to customer's requirement as 12V/24VDC, 48V/60VDC, 60V/72VDC



  +86 19505870521
  sales2@bwinverter.com
E-mail

Share:

BCM-1500 Modified Sine Wave Inverter

Models includes: 12VDC 1500W, 24VDC 1500W, 48V 1500W, 12V/24VDC 1500W, 48V/60VDC 1500W, 60V/72VDC 1500W

Output Voltage Available: 100VAC/120VC/220VAC/230VAC/240VAC

Frequency : 50HZ/60HZ

Socket type: can be customized

OEM and ODM are available

1 AC socket, 1 digital display, 1 OFF/ON switch, 1 intelligent cooling fan


Model BCM-1500-12 BCM-1500-12/24 BCM-1500-48/60
Output AC voltage 100/110/120/220/230/240VAC
Rated power 1500W 1500W 1500W
Surge power 3000W
Waveform Modified Sine Wave
Frequency 50/60Hz±3Hz
Input DC voltage 12V 12V 24V 48V 60V
Voltage range 10 ~ 15 VDC 10 ~ 15 VDC 20 ~ 30 VDC 40 ~60 VDC 50 ~ 72 VDC 50 ~ 72 VDC
Efficiency >89.0% >89.0% >92.0% >92.0% >92.0%
Protection Bat.low voltage alarm 11 ± 0.5 VDC 11 ± 0.5 VDC 22 ± 0.5 VDC 44 ± 1 VDC 55 ± 2 VDC
Bat.low voltage shut down 10 ± 0.5 VDC 10 ± 2 VDC 20 ± 0.5 VDC 40 ± 1 VDC 50 ± 2 VDC
Overload Shutdown,then start automatically.
Over voltage 15 ± 0.5 VDC 15 ± 0.5 VDC 30 ± 0.5 VDC 60 ± 1 VDC 72 ± 2 VDC
Over temperature Shut-off output voltage, recover automatically after temperature goes down
Short circuit Shut-off output voltage, restart to recover
Bat.reverse polarity Reverse protection circuit- fuses will not burn
Environment Reset voltage after LVS 10.5 ± 0.5 VDC 10.5 ± 0.5 VDC 21 ± 1 VDC 42 ± 2 VDC 53 ± 1 VDC
Working Temp -20~40ºC
Other weight 1.55KG
Dimension 268*135*60mm
Packing 1.75(300*16*6cm), 20pcs/35Kg/Ctn(46*34*32cm)
Cooling fan Controlled by load and temperature
Display LED Display(Display battery voltage , power, temperature and fault code)
Warranty 12Months
These data are from our laboratory. The input voltage can be with single and double and customized