It is a modified sine wave inverter and provides 2200 w continuous DC to AC power and 4400 w surge power.
1. Aluminum-magnesium alloy shell, lightweight, good thermal conductivity, can quickly reduce the temperature of components,
2. Smart Digital Display: Show Input Voltage, Power, Temperature, and Protection code in time. The protection code as: P-1: Overload Protection; P-2: Low voltage protection; P-3: Over voltage protection; P-4: Overheat protection; P-5: Short-circuit protection P-6: System Fault
3. Intelligent Silent Cooling Fan: It can minimize noises and extend the life of the inverter
4. Buzzer reminder: Once any protection mode of the inverter is triggered, the inverter will immediately disconnect the output voltage, and the buzzer reminds users that the inverter is in the protection mode.
5. Automatic shutdown protection and unique circuit to protect against Over-Voltage/Low-Voltage/Over-load/Short Circuit/Over Heat/Reverse Polarity
6. Supports a wide range of input voltage, which is suitable for different Battery types such as GEL, AGM, LFP, etc.
7. Double Input voltage design according to customer's requirement as 12V/24VDC, 48V/60VDC, 60V/72VDC
sales2@bwinverter.com
Share:
BCM-2200 Modified Sine Wave Inverter
Models includes: 12VDC 2200W, 24VDC 1700W, 48V 2200W, 12V/24VDC 2200W, 48V/60VDC 2200W, 60V/72VDC 2200W
Output Voltage Available: 100VAC/120VC/220VAC/230VAC/240VAC
Frequency : 50HZ/60HZ
Socket type: can be customized
OEM and ODM are available
1 AC socket, 1 digital display, 1 OFF/ON switch, 2 intelligent cooling fans
Model | BCM-2200-12 | BCM-2200-12/24 | BCM-2200-48/60 | ||||
---|---|---|---|---|---|---|---|
Output | AC voltage | 100/110/120/220/230/240VAC | |||||
Rated power | 2200W | 2200W | 2200W | ||||
Surge power | 4400W | ||||||
Waveform | Modified Sine Wave | ||||||
Frequency | 50/60Hz±3Hz | ||||||
Input | DC voltage | 12V | 12V | 24V | 48V | 60V | |
Voltage range | 10~15 VDC | 10~15 VDC | 20~30 VDC | 40~60 VDC 50~72 VDC | 50~72 VDC | ||
Efficiency | >89.0% | >89.0% | >92.0% | >92.0% | >92.0% | ||
Protection | Bat.low voltage alarm | 11±0.5 VDC | 11±0.5 VDC | 22±0.5 VDC | 44±1 VDC | 55±2 VDC | |
Bat.low voltage shut down | 10±0.5 VDC | 10±2 VDC | 20±0.5 VDC | 40±1 VDC | 50±2 VDC | ||
Overload | Shutdown,then start automatically. | ||||||
Over voltage | 15±0.5VDC | 15±0.5VDC | 30±0.5VDC | 60±1VDC | 72±2 VDC | ||
Over temperature | Shut-off output voltage, recover automatically after temperature goes down | ||||||
Short circuit | Shut-off output voltage, restart to recover | ||||||
Bat.reverse polarity | Reverse protection circuit- fuses will not burn | ||||||
Environment | Reset voltage after LVS | 10.5± 0.5 VDC | 10.5± 0.5 VDC | 21±1 VDC | 42±2 VDC | 53±1 VDC | |
Working Temp | -10~50ºC | ||||||
Other | weight | 2.45KG | |||||
Dimension | 353*182*72mm | ||||||
Packing | 2.7Kg(35*25*12cm), 10pcs/28Kg/Ctn(46*34*32cm) | ||||||
Cooling fan | Controlled by load and temperature | ||||||
Display | LED Display(Display battery voltage , power, temperature and fault code) | ||||||